Ventilator


AERECO STANDARD - HUMIDITY CONTROLLED VENTILATOR WITH STANDARD DRIP

The most popular of all humidity controlled ventilators. It is available in two types of movement and in 3 different colours. Aesthetic construction and reliability have made the ventilator EMM to become the most popular product Aereco. Along with the acoustic drip it provides the acoustic insulation of 37 dB.
Humidity controlled system: change in flow depends on the level of relative humidity. Sound insulation: up to Dn,e,w = 37 dB with an acoustic drip. Simple maintenance: the user does not regulate the flow. Periodically the housing shall be cleaned. Directing of an air stream: depending on the settings: a vertical or diagonal stream. EMM ventilator can be operated in two positions depending on the stand mount.
Air stream is directed vertically or diagonally. Setting depends on the distance to the ventilator from the external reveal (too small distance suppresses the free flow of air through the ventilator). EMM ventilators can be equipped with a manual blockade of air flow. Half-closed ventilators allow to achieve the minimum amount of air. This option is recommended to be used only by the unfavourable climatic conditions.

EMM the most popular Aereco product

37 DB AERECO ACOUSTIC - ACOUSTIC HUMIDITY CONTROLLED VENTILATOR

EHA ventilator can be installed directly on the window or on the roller shutters box. Thanks to its design it provides maximum acoustic protection while at the same time optimizes the supply of air to the rooms.
Humidity controlled system: change in flow is dependent on the level of relative humidity. Sound insulation: up to Dn,e,w = 42 dB with accessories. Simple maintenance: user does not regulate the flow. Periodically the housing of ventilator shall be cleaned. The ventilator together with an acoustic connector and drip provides insulation up to 42 dB*.
* Ventilator EHA with a standard drip provides an insulation of 37 dB. Ventilator EHA can be equipped with a manual blockade of the air flow. Half closed ventilators allow to provide a minimum amount of air. This option is recommended to be used only by the unfavourable climatic conditions.

EHA ventilator maximum acoustic protection

AMI AERECO

Self-controlling. Quantity of supplied air depends on the pressure difference outside and inside the room. This is the level of differential pressure at which the performance of the ventilator reaches the maximum value. With further increase in the wings turn limiting the supply of air. Such a situation may be caused, for example by the wind.
The user has the possibility to close the flap reducing the airflow to minimum. The ventilator is designed for PVC and wooden windows. Airflow: 22-30m³/h. When the flap is in the open position, the amount of the supplied air depends on the pressure difference inside and outside the room. The air flow depends on the type of ventilator and achieves up to 22/30 m³/h. Reaching the maximum value the flaps located inside the ventilator turn to limit the amount of delivered air.
However after setting the flap in the closed position, the ventilator provides a minimum amount of air. Outside air passes through the ventilator and it is directed upwards, above the zone of human presence, thus preventing the unpleasant draft and the feeling of discomfort of users. Acoustic damping of the set at the open ventilator is 38dB (A).

2MO102 AERECO - PRESSURE VENTILATOR AMO

Self-controlling.
Quantity of supplied air depends on the pressure difference outside and inside the room. It occurs to the level of pressure difference at which the performance of the ventilator reaches the maximum value. With further increase the flaps turn to limit the amount of delivered air. Such a situation may be caused, for example by the wind. The user has the possibility to close the flaps to limit the air flow to a minimum.
Airflow: 22/30/45 m³/h. When the flap is set in the open position, the amount of supplied air depends on the pressure difference inside and outside the room. The air flow depending on the ventilator reaches up to 22/30/45 m³/h. After reaching the maximum value the flaps located inside the ventilator turn to limit the amount of delivered air.
However after setting the flaps in the closed position, the ventilator provides a minimum amount of air. Outside air passes through the ventilator and it is directed upwards, above the zone of human presence, thus preventing the unpleasant draft and the feeling of discomfort of users.




 
           
           
   
4.468 MB   3.250 MB
Last update: 27.03.2017 - 13:29
Always actual and interesting information on
Kołobrzeska Fabryka Okien - Amberline Sp. z o.o.
ul. Krzysztofa Kolumba 20 | 78-100 Kołobrzeg
Tel.: +48 94 / 35 51 820 | Fax: +48 94 / 35 51 821
Internet: www.amberline.eu | E-mail: info@amberline.eu